capture zone

capture zone

capture zone uses 3d streamlines technology to determine the volumetric regions of your model for which groundwater flow will be captured by one or more extraction wells.

A streamline is traced from each cell of the input field through the seepage velocity field (typically from seepage velocity). When a streamline passes within the Well Capture Distance of a well location (from the Well Nodes port), its starting cell is deemed to have been captured by that well.

The output is a multi-block field with one block per well, each holding only the input cells captured by that well. Each block carries a constant Well Number node data component, plus Time to Capture and Distance to Extinction cell data components, so the capture zone of each well can be displayed and colored separately.

Ports

DirectionNameTypeDescription
InputInput FieldFieldA field containing vector data representing seepage velocity.
InputWell NodesFieldThe field containing nodes to use as well locations.
OutputOutput FieldFieldA multi-block field containing one block per well; each block holds only the input cells captured by that well. Each block has a constant Well Number node data component (range covers all wells) plus Time to Capture and Distance to Extinction cell data components.
OutputOutput ObjectRenderableA renderable object showing the captured cells.

Properties

PropertyTypeDescription
Allow RunBooleanSpecifies whether the module is permitted to execute. Set to True to enable execution.
ExecuteButtonForces the module to run even if Allow Run is disabled.
Seepage Velocity ComponentChoiceSelects which vector data component of the input field is used as the seepage velocity for streamline integration.
Velocity UnitsStringSpecifies the units of the input vector data. By default (linked) this is determined from the input field. Unlink to override manually.

Terminating Conditions

PropertyTypeDescription
Well Capture DistanceDoubleThe maximum distance that a streamline must pass near an extraction well before that streamline’s integration is terminated and its starting cell is deemed to have been captured by a well. Setting this value too high may result in cells being designated as captured that are not. Setting it too low may result in incorrect determination of which (if any) well is responsible for capturing cells. A value corresponding to one nominal cell width in the region of the wells is generally appropriate.
Max Segments TotalIntegerThe maximum allowable number of streamline segments that will be completed for each streamline. If the number of segments along a streamline exceeds the max number, the streamline is terminated at the end of the last (max) segment.
Minimum VelocityDoubleThe minimum velocity that will be considered in the integration. If the magnitude of the velocity field in a region is less than this minimum value, streamlines will end in that region (or will not be produced if the velocity at a starting point is less than the minimum). Setting this to a lower value will produce longer (and typically more) streamlines. Higher values tend to produce shorter and fewer streamlines.
Extinction AngleDoubleThe maximum allowable angle between successive line segments before integration (streamline generation) is terminated.

Output Data Options

PropertyTypeDescription
Export Well DataBooleanUses the selected scalar data component on the Well Nodes input as the Well Number output value instead of the well index.
Pass Node DataBooleanControls whether node (point) data from the Input Field is passed through to the output. When off, the output node data contains only the Well Number array generated by this module.
Pass Cell DataBooleanControls whether cell data from the Input Field is passed through to the output. When off, the output cell data contains only the Time to Capture and Distance to Extinction arrays generated by this module.
Log Process TimeBooleanSpecifies that time data will be output on a logarithmic scale. This converts all time values to absolute.
Time MinimumDoubleThe minimum value time data is clamped to before log processing. Useful to avoid datamap issues for very small time values. Enabled when Log Process Time is on.